JP EN
Calculations 81-6-6472-4772 Contact
Calculations for head plates and conical heads

various calculations, including capacity calculations are available for your use.
*The actual measurements may differ from the calculation result due to a tolerance.

[SD] Standard flanged dished head [ED] Ellipsoidal dished head Special dished head [FH] Flanged only head [DR] Dished only head [HH] Hemispherical head [C] Conical head: Type A [CH] Conical head: Type B [CR] Conical reducer: Type C [SD] Change in capacity of standard flanged dished head [ED] Change in capacity of ellipsoidal dished head

Contact

Please feel free to contact us if you have any questions, requests, or products that other manufacturers have refused to produce.

Inner surface area, overall capacity, and product weight of head plates

[SD] Standard flanged dished head

[SD] Standard flanged dished head
D:
mm
ℓ:
mm
t:
mm
Specific gravity:

Inner surface area:
Overall capacity:
Unit weight:
kg

[ED] Ellipsoidal dished head

[ED] Ellipsoidal dished head
D:
mm
ℓ:
mm
t:
mm
Specific gravity:

Inner surface area:
Overall capacity:
Specific gravity:
kg

Special dished head

Special dished head
D:
mm
R:
mm
r:
mm
ℓ:
mm
t:
mm
Specific gravity :

Inner surface area:
Overall capacity:
Unit weight:
kg

[FH] Flanged only head

[FH] Flanged only head
D:
mm
r:
mm
ℓ:
mm
t:
mm
Specific gravity:

Inner surface area:
Overall capacity:
Unit weight:
kg

[DR] Dished only head

[DR] Dished only head
R:
mm
H:
mm
t:
mm
Specific gravity:

Inner surface area:
Overall capacity:
Unit weight:
kg

[HH] Hemispherical head

[HH] Hemispherical head
D:
mm
t:
mm
Specific gravity:

Inner surface area::
Overall capacity:
Unit weight:
kg

Inner surface area, overall capacity and product weight of conical heads (angle: radian)

[C] Conical head: Type A

[C] Conical head: Type A
D:
mm
d:
mm
h:
mm

Inner surface area::
Overall capacity:

[CH] Conical head: Type B

[CH] Conical head: Type B
D:
mm
D1:
mm
d:
mm
r:
mm
h1:
mm
h2:
mm
α:
°

Inner surface area::
Overall capacity:

[CR] Conical reducer: Type C

[CR] Conical reducer: Type C
D:
mm
D1:
mm
D2:
mm
d:
mm
R:
mm
r:
mm
h1:
mm
h2:
mm
h3:
mm
α:
°

Inner surface area::
Overall capacity:

Change in capacity of standard flanged dished head (excluding the flange) (angle: radian)

[SD] Change in capacity of standard flanged dished head

[SD] Change in capacity of standard flanged dished head
D:
mm
h:
mm

Capacity:
Calculate assuming ℓ = 1/1000㎥

[SD] Change in capacity of standard flanged dished head
D:
mm
h:
mm

Capacity:
Calculate assuming ℓ = 1/1000㎥

※It is difficult to express change in capacity by a theoretical formula in this case. Use the result only as a guide.

2:1 Change in capacity of 2:1 ellipsoidal dished head (excluding flange)

[ED] Change in capacity of ellipsoidal dished head

[ED] Change in capacity of ellipsoidal dished head
D:
mm
h:
mm

Capacity:
Calculate assuming ℓ = 1/1000㎥

D:
mm
h:
mm

Capacity:
Calculate assuming ℓ = 1/1000㎥